PROBLEM
The motor does not start
but override works
Pump running continuously
Pump starting up
intermittently
16
DISMANTLING
The unit beeps to show that it
is no longer under power.
Unclip the cover.
Unscrew the metal clamp
A
on the motor (the check valve
stays in place while the motor
is being repaired).
Unscrew the metal clamp
B
.
Remove the motor power
wires
C
from the screw
connector.
Remove the screws
D
from
the inspection cover.
Use the handle
E
to lift the
motor carefully.
If the faulty motor has to be
sent back to the manufacturer
remove screws
F
from the
inspection cover.
INSTALLING A MOTOR
Remove the plug and the
inspection cover.
Screw the motor onto the
inspection cover and put the
cover back in place.
Reconnect the motor power
wires (cf. illustration ).
Warning:
Comply carefully with the
color code:
Blue wire with the blue wire
Brown wire with the brown
wire
Green wire with the green
wire
White wire with the white wire
Connect the unit to the power
supply.
Carry out a complete test for
commissioning.
15
WORK THAT MAY BE REQUIRED
ELECTRICAL INSTALLATION MUST BE CARRIED
OUT BY A PROFESSIONAL ELECTRICIAN
Before carrying out any other types of work, disconnect the Sanicubic
®
1
from the power supply.
INSTRUCTIONS ONLY FOR QUALIFIED PROFESSIONAL SPECIALISTS
UNIT ALARM
INSTRUCTIONS RESERVED EXCLUSIVELY FOR
QUALIFIED PROFESSIONAL SPECIALISTS
PROBABLE CAUSES
1 – Faulty electronic card
2 – Faulty detection system
1 – Obstructed discharge pipe
2 – Pump discharge height
too high
3 – Faulty electronic card
1 – The non-return valve is
leaking or broken
SOLUTIONS
1 – Contact Saniflo after-sales
service
1 – Remove obstruction from
the discharge pipe
2 – Check installation (**)
3 – Contact Saniflo after-sales
service
1 – Clean or change the valve
Possible secondary maintenance operations
PROBLEM
No motor starts and the
power yellow LED is off (*)
The LED warning light is on
The LED flashing warning
light
PROBABLE CAUSES
No power
1 – Obstructed pump
2 – Blocked up pump
Faulty detection system
SOLUTIONS
Check your electrical
connections
Press the override button
continuously to get the
pumps working
Contact Saniflo after sales
service
Possible preliminary maintenance operations on the unit
(*) A flashing yellow LED indicates that there has been a power cut.
(**) Warning: if pumping height is high, 90° elbows should be avoided.
16
4
F
DISCONNECT THE UNIT FROM
POWER SUPPLY (the green indicator
light must be off).
16
1
A
16
2
B
C
16
3
D
E