GENERAL DESCRIPTION
This appliance may be used to pump waste water produced by various
bathroom appliances and plumbing fixtures, as shown in fig. (see
technical data sheet).
SANISHOWER
®
may be used to pump waste water from a shower,
sink or other low pressure appliances. It can pump hot water up to
a maximum of 104°F (4C).
SANIVITE
®
P110 may be used to pump water from a bath or larger
capacity sink. It can also pump water and suds from a washing
machine and dishwasher (the use of low suds detergent is
recommended. Note that the washing machine must be connected to
the pump via an indirect connection (such as a laundry tub or utility
sink).
For further details, please consult pump level curves (see fig. ,
in the technical data sheet).
Pumping system must discharge into a minimum 3-inch sanitary
drainage pipe. If you require a vertical lift it should precede any
horizontal” run and should commence as near as possible to the
discharge elbow. Once you have started the horizontal run, you
cannot change directions in a vertical manner.
If you wish the unit to pump vertically and horizontally you may calculate
that 3 feet of vertical lift is equivalent to 30 feet of “horizontal run. (see
fig.6, in the technical data sheet).
Each bend or change of direction causes minor losses, which must be
deducted from the discharge performance figures in accordance with
the usual head loss practice. (Rough guide: reduce discharge height
by 3 feet for each 90° bend).
5
1
4
NOTICE
This pump has been developed in compliance with the highest
standards of quality control in an AFAQ certified ISO 9001 plant
(version 2000). In order to ensure optimal performance of this
appliance, the installation and maintenance instructions,
described in this notice, must be strictly followed, especially,
those instructions that are accompanied by the symbol:
" " which refers to specific instructions, which if not respected,
may cause a risk to the safety of the person,
" " which indicates the possibility of an electric hazard or risk
"
ATTENTION" referring to specific instructions, which if not
respected, may cause the appliance to malfunction.
In order to enjoy maximum comfort from this appliance, please
carefully read the assembly instructions given in Section .
Note that this pump is not suitable for underground installation
and not to be installed in hazardous locations.
7
1
LIST OF PARTS SUPPLIED
See fig. (technical data sheet).
2
2
DIMENSIONS AND CLEARANCE
See fig. (technical data sheet).
3
3
PERFORMANCE CURVES
See fig. (technical data sheet).
5
5
HEIGHT AND LENGTH OF DRAIN
The possible combinations of height and length are shown in
fig. (see technical data sheet).
6
6
INSTALLATION
The appliance must be installed in such a way as to ensure easy
access for repair and maintenance.
7
ELECTRICAL CONNECTIONS
All electrical connections must comply with local codes in your
region. The current must be single phase120 V, 15 A. The
electrical outlet must be located at a minimum distance of 40 inches
from the shower or bath. Only connect this appliance to a breaker
protected outlet in case or ground default.
Attention: Electrical hazard – this appliance is equipped with a
ground conductor and a ground to reduce the risk of electrocution:
make sure your appliance is connected to an electric circuit that
has a grounded receptacle (GFCI).
SANIVITE
®
P110 CONNECTION
Connection to side inlets
For connections to bathroom or kitchen appliances that have side
inlets to water tank or basin, use coupling sleeve A or coupling
sleeve A' and fasten with clamps (see fig. n°7a in the technical
data sheet).
Use plugs C to block unused inlet or inlet valves by tightening
plugs a 1/4 turn (grease joints first).
Connection to inlet valve on cover
To connect a bathroom appliance to the lid inlet, use a coupling
sleeve. Fasten with clamps (see fig. n°7c in the technical data
sheet).
Installing shower or bath tub
To connect a bath (or a shower), be sure to raise base at least
6-8 inches (see fig. n°7d in the technical data sheet).
Connection to drain
The appliance should be drained by using a 1 inch diameter pipe
(copper or PVC, CPVC, etc). The connection to the drain stack
must be made with a Y type connection, approved for such purpose.
In case of doubt, have a plumber complete the installation.
The plastic discharge elbow/check valve assembly should be
inserted (long end) into the rubber hose located on the top of the
lid. The step-down rubber fitting should then be inserted at the
discharge side of the elbow assembly and secured with the
provided metal clamps. The step-down rubber needs to be cut to
fit the discharge pipe diameter of one inch. Three metal clamps
should be used to secure all fittings.
Ensure that the angle of slope is
1
/4 inch per foot for horizontal
drain sections, leading up to main drain stack, to ensure drainage
by gravity.
Install an optional full port valve at the bottom of the drain pipe
riser to allow drain off in case of repairs (see fig. n°7f in the
technical data sheet).
Use long turn bends and not elbows, elbows are not normally
available in plastic piping, use two 45 degree elbow pieces back
to back to make a 90 degree elbow.
Connection to a vent system (7b)
These pumps are designed to be connected to a ventilation
system. Such connections must comply with local codes and this
manual. This unit has been designed with a vent connection on
the top of the pump.
All plumbing codes require connection to a vent system.
Connect your vent system using a 1-1/2” PVC or ABS pipe.
Please note that the vent system should be a two-way air vent.
The use of mechanical vents, air admittance valves or similar
devices are not permitted as these are considered one-way
air vent systems. Note that the breather hole (1/2” opening)
should be plugged for North American Installations.
SANISHOWER
®
CONNECTION
Connection to side inlets
For connections to bathroom fixtures that have side inlets to water
tank or basin, use coupling sleeve A and fasten with clamps (see
fig. n°7a in the technical data sheet).
Installing shower
To connect a shower, be sure to raise base at least 6-8 inches
(see fig. n°7d in the technical data sheet).
7.3
7.2
7.1
8399 202 SANIVITE_2FSANISHOWER V2010.qxd:5036 NOTICE 220 F/GB 18/03/10 20:06 Page2